Overview
Main Features
- Pure sine wave output
- IP65 waterproof and dustproof
- Self-consumption and Feed-in to the grid
- Programmable supply priority for PV, Battery or Grid
- Reserved communication port for BMS (RS485)
- User-adjustable charging current and voltage
- Programmable multiple operation modes: Grid-tie, off-grid, and grid-tie with backup
- Monitoring software for real-time status display and control
- Parallel operation up to 9 units
Specifications
MODEL | Infini VII WP 2KW | Infini VII WP 3KW | Infini VII WP 5KW | |
PHASE | 1-phase in/1-phase out | |||
Maximum PV Input Power | 3000W | 4000W | 6000W | |
Rated Output Power | 2000VA/2000W | 3000VA/3000W | 5000VA/5000W | |
Maximum Charging Power | 2000W | 3000W | 4000W | |
GRID-TIE OPERATION | ||||
PV INPUT (DC) | ||||
Nominal DC Voltage / Maximum DC Voltage | 400 VDC | 450 VDC | 500 VDC | |
Start-up Voltage / Initial Feeding Voltage | 120VDC / 150 VDC | |||
MPPT Voltage Range | 120 VDC ~ 400 VDC | 120 VDC ~ 450 VDC | ||
Number of MPP Trackers/Max. Input Current | 1 / 10A | 1 / 18A | 1 / 27A | |
GRID OUTPUT (AC) | ||||
Nominal Output Voltage | 220/230/240 VAC | |||
Output Voltage Range | 184 – 264.5 VAC or 195.5 – 253 VAC (Selectable) | |||
Nominal Output Current | 8.7A | 13A | 21.7A | |
Power Factor | > 0.99 | |||
EFFICIENCY | ||||
Maximum Conversion Efficiency (DC/AC) | 0.96 | |||
OFF-GRID OPERATION | ||||
AC INPUT | ||||
AC Start-up Voltage / Auto Restart Voltage | 120 – 140 VAC / 180 VAC | |||
Acceptable Voltage Range | 90 – 280 VAC or 170 – 280 VAC | |||
Maximum AC Input Current | 20A | 30A | 40 A | |
Frequency Range | 50 Hz/60 Hz (Auto sensing) | |||
PV INPUT (DC) | ||||
Maximum DC Voltage | 400 VDC | 450 VDC | 500 VDC | |
MPPT Voltage Range | 120 VDC ~ 400 VDC | 120 VDC ~ 450 VDC | ||
Number of MPP Trackers/Max. Input Current | 1 / 10A | 1 / 18A | 1 / 27A | |
BATTERY Mode Output (AC) | ||||
Nominal Output Voltage | 220/230/240 VAC | |||
Output Waveform | Pure Sine Wave | |||
Efficiency (DC to AC) | 0.92 | 93% | ||
HYBRID OPERATION | ||||
PV INPUT (DC) | ||||
Nominal DC Voltage / Maximum DC Voltage | 400 VDC | 450 VDC | 500 VDC | |
Start-up Voltage / Initial Feeding Voltage | 120VDC / 150 VDC | |||
MPPT Voltage Range | 120 VDC ~ 400 VDC | 120 VDC ~ 450 VDC | ||
Number of MPP Trackers/Max. Input Current | 1 / 10A | 1 / 18A | 1 / 27A | |
GRID OUTPUT (AC) | ||||
Nominal Output Current | 18A | 13A | ||
Nominal Output Voltage | 220/230/240 VAC | |||
Output Voltage Range | 184 – 264.5 VAC or 195.5 – 253 VAC (Selectable) | |||
AC INPUT | ||||
AC Start-up Voltage / Auto Restart Voltage | 120 – 140 VAC / 180 VAC | |||
Acceptable Voltage Range | 90 – 280 VAC or 170 – 280 VAC | |||
Maximum AC Input Current | 20A | 30A | 40 A | |
BATTERY MODE OUTPUT (AC) | ||||
Nominal Output Voltage | 220/230/240 VAC | |||
Efficiency (DC to AC) | 0.92 | 0.93 | ||
BATTERY & CHARGER | ||||
Nominal DC Voltage | 48 VDC | |||
Maximum Charging Current | 40 A | 60 A | 80 A | |
Maximum Solar Charging Current | 40 A | 60 A | 80 A | |
Maximum AC Charging Current | 40 A | 60 A | 80 A | |
GENERAL | ||||
PHYSICAL | ||||
Dimension, D X W X H (mm) | 200 x 350 x 592.7 | |||
Net Weight (kgs) | 20 | |||
INTERFACE | ||||
Parallel Function | Yes, 9 units | |||
Communication Port | USB or RS-232/Dry Contact/RS485 | |||
ENVIRONMENT | ||||
Operating Humidity | 0~95% RH (Non-condensing) | |||
Operating Temperature | -25°C to 50°C |